Difference between revisions of "Accessories"

From Dental Wiki
Jump to navigation Jump to search
(Marked this version for translation)
 
(15 intermediate revisions by 2 users not shown)
Line 4: Line 4:
  
 
<!--T:3-->
 
<!--T:3-->
The Open Technologies' NeWay Scanners come with a fixed set of basic accessories and some extra accessories that depend on the specific scanner model.
+
The Open Technologies' NeWay Scanners come with a fixed set of basic accessories. Some extra accessories are also available, depending on specific requirements.
  
 
==Base Kit== <!--T:4-->
 
==Base Kit== <!--T:4-->
  
 
<!--T:5-->
 
<!--T:5-->
The Basic Kit comes with every scanner, inside a case, containing the model holder, the multi-die holder and the calibration kit.
+
The Basic Kit comes with every scanner, inside a case, containing the model holder, the multi-die holder, the calibration kit, the reference rim and the articulator plate.
  
 
===Model Holder=== <!--T:6-->
 
===Model Holder=== <!--T:6-->
  
 
<!--T:7-->
 
<!--T:7-->
The Model Holder is the main support on which it's possible to place jaws or other objects inside the scanner. If mounted on this support, the objects are guaranteed to be in the best possible position for the scanner acquisition.
+
The Model Holder is the main support on which it's possible to place models or other objects inside the scanner. If mounted on this support, the objects are guaranteed to be in the best possible position for the scanner acquisition.
  
 
<!--T:8-->
 
<!--T:8-->
Line 20: Line 20:
  
 
<!--T:9-->
 
<!--T:9-->
[[File:Model-holder.png|300px]]
+
[[File:Model-holder.jpg|300px]]
  
  
Line 32: Line 32:
  
 
<!--T:13-->
 
<!--T:13-->
[[File:Model_multidie.png|300px]]
+
[[File:Multidie-no-reference.jpg|300px]]
  
 
===Calibration Kit=== <!--T:14-->
 
===Calibration Kit=== <!--T:14-->
Line 46: Line 46:
  
 
<!--T:17-->
 
<!--T:17-->
[[File:Calibration_kit.jpg|300px]]
+
[[File:master.jpg|300px]]
 +
 
 +
==Reference Rim== <!--T:33-->
 +
 
 +
<!--T:34-->
 +
The Reference Rim offers reference points to grant accurate dimensional results during the scanning process. Allthough dimensional accuracy is granted for the vast majority of all objects, in case of scanning small metalic objects, such as metal abutments, or other difficult materials, the Reference Rim offers even better results and safety.
 +
 
 +
<!--T:46-->
 +
'''NOTE THAT THE REFERENCE RIM IS A PRECISION OBJECT! OCCLUSAL AND WHITENING SPRAYS, AND CLEANING SOLVENTS, DAMAGE ITS SURFACE!'''
 +
'''DO NOT SPRAY ANY SUBSTANCE ON THE RIM AS TO DO SO IT WILL NO LONGER BE USABLE FOR SCANNING NOR FOR CALIBRATING!'''
 +
 
 +
<!--T:47-->
 +
[[File:reference rim.png|300px]]
 +
 
 +
==Articulator Plate== <!--T:36-->
 +
 
 +
<!--T:37-->
 +
The Articulator plate allows to scan any kind of articulator in the NeWay scanner, thanks to its ample diameter.
 +
 
 +
<!--T:38-->
 +
[[File: piattello-articolatore.jpg|300px]]
  
 
==Dynamic Articulation Module== <!--T:18-->
 
==Dynamic Articulation Module== <!--T:18-->
Line 56: Line 76:
  
 
<!--T:21-->
 
<!--T:21-->
Up to the present, our dynamic articulation module supports 4 different mounting plates.
+
Up to the present, our dynamic articulation module supports 6 different mounting plates.
  
 
<!--T:22-->
 
<!--T:22-->
* Artex : [[File:Basetta_artex.jpg|300px]]
+
* Artex : [[File:basetta_artex.jpg|300px]]
* Kavo : [[File:Basetta_cavo.jpg|300px]]
+
* Kavo : [[File:basetta_protar.jpg|300px]]
* Adesso : [[File:Basetta_adesso.jpg|300px]]
+
* Adesso : [[File:basetta_adesso.jpg|300px]]
* Sam : [[File:Basetta_sam.jpg|300px]]
+
* Sam : [[File:basetta_sam.jpg|300px]]
* Bioart : [[File:Basetta_bioart.jpg|300px]]
+
* Bioart : [[File:basetta_a7.png|300px]]
* Denar : [[File:Basetta_denar.jpg|300px]]
+
* Denar : [[File:basetta_denar.jpg|300px]]
 
 
 
 
  
 
===Axis Calibration Object=== <!--T:23-->
 
===Axis Calibration Object=== <!--T:23-->
Line 77: Line 95:
  
 
<!--T:26-->
 
<!--T:26-->
[[File:Kavo_oggettotest.jpg|300px|]]
+
[[File:oggetto-test.png|300px|]]
  
 
===Concept Quad Support=== <!--T:27-->
 
===Concept Quad Support=== <!--T:27-->
Line 88: Line 106:
  
 
<!--T:30-->
 
<!--T:30-->
[[File:Concept_holder.png|300px]]
+
[[File:concept-quad.jpg|300px]]
 +
 
 +
===Accessories Tray=== <!--T:39-->
 +
 
 +
<!--T:40-->
 +
All these accessories can be kept and organized in Open Technologies Accessories' tray.
 +
 
 +
<!--T:41-->
 +
[[File:vassoio-porta-accessori.png]]
 +
 
 +
===TouchScreen Monitor=== <!--T:42-->
 +
 
 +
<!--T:43-->
 +
1Clik can also be used with any kind of touchscreen monitor. <br/>
 +
Open Technologies provides Dell 24 – P2418HT LED-backlit LCD monitor.
 +
 
 +
<!--T:44-->
 +
[[File:DellMonitor.png]]
 +
 
 +
===3DMouse=== <!--T:45-->
 +
1Clik can also be used with any kind of 3DMouse (item not provided by Open Technologies- to be purchased separately).
  
 
  </translate>
 
  </translate>
 +
{{Navigation|Pc_Connection|Implant_Library}}

Latest revision as of 09:35, 2 May 2018

Accessories

The Open Technologies' NeWay Scanners come with a fixed set of basic accessories. Some extra accessories are also available, depending on specific requirements.

Base Kit

The Basic Kit comes with every scanner, inside a case, containing the model holder, the multi-die holder, the calibration kit, the reference rim and the articulator plate.

Model Holder

The Model Holder is the main support on which it's possible to place models or other objects inside the scanner. If mounted on this support, the objects are guaranteed to be in the best possible position for the scanner acquisition.

It's important to keep the model holder clean and black to reduce the possible interferences between the model holder and the object during the acquisition phase.

Model-holder.jpg


Multi-Die Support

The Multi-Die support is used to acquire multiple stumps with a single acquisition. The position are later automatically identified by the software.

It's important to keep the Multi-Die clean and black to reduce the possible interferences between the Multi-Die and the object during the acquisition phase.

Multidie-no-reference.jpg

Calibration Kit

The Calibration Kit is a planar surface with a pattern of circles, placed on a bended support.
Every calibration kit is measured and analized with high-precision machines.
The measurement is then saved on a xml file and every kit has it's own xml description file.
The kit is used to recalibrate the optical head of the scanner.

It's really important to handle the kit with care and to avoid touching the planar surface. Every modification of the planar surface, like scratches or dirt, can make the calibration system unreliable.

Master.jpg

Reference Rim

The Reference Rim offers reference points to grant accurate dimensional results during the scanning process. Allthough dimensional accuracy is granted for the vast majority of all objects, in case of scanning small metalic objects, such as metal abutments, or other difficult materials, the Reference Rim offers even better results and safety.

NOTE THAT THE REFERENCE RIM IS A PRECISION OBJECT! OCCLUSAL AND WHITENING SPRAYS, AND CLEANING SOLVENTS, DAMAGE ITS SURFACE! 
DO NOT SPRAY ANY SUBSTANCE ON THE RIM AS TO DO SO IT WILL NO LONGER BE USABLE FOR SCANNING NOR FOR CALIBRATING! 

Reference rim.png

Articulator Plate

The Articulator plate allows to scan any kind of articulator in the NeWay scanner, thanks to its ample diameter.

Piattello-articolatore.jpg

Dynamic Articulation Module

In order to use the dynamic articulation module, some special supports are needed: a specific Axis Calibration Object and a special Mounting Plate for every supported articulator.

Mounting Plates

Up to the present, our dynamic articulation module supports 6 different mounting plates.

  • Artex : Basetta artex.jpg
  • Kavo : Basetta protar.jpg
  • Adesso : Basetta adesso.jpg
  • Sam : Basetta sam.jpg
  • Bioart : Basetta a7.png
  • Denar : Basetta denar.jpg

Axis Calibration Object

This is a specific object, which fits on every mounting plate, used to calibrate the movement system for the Dynamic Articulation Module.

It's important to keep the object clean and handle it with care. Every modification of the object surface, like scratches or dirt, can make the calibration system unreliable.

Oggetto-test.png

Concept Quad Support

The Concept Quad Support is provided together with the additional Concept Quad Scanning Module and it allows to place two antagonist quadrant models and their stumps in the scanner to be scanned in together at the same time.

It's important to keep the model holder clean and black to reduce the possible interferences between the model holder and the object during the acquisition phase.

Concept-quad.jpg

Accessories Tray

All these accessories can be kept and organized in Open Technologies Accessories' tray.

Vassoio-porta-accessori.png

TouchScreen Monitor

1Clik can also be used with any kind of touchscreen monitor.
Open Technologies provides Dell 24 – P2418HT LED-backlit LCD monitor.

DellMonitor.png

3DMouse

1Clik can also be used with any kind of 3DMouse (item not provided by Open Technologies- to be purchased separately).


Navigation Back.png Homebutton.png Navigation Next.png