(Created page with "Esistono 2 tipi di calibrazione: ; Ricalibrazione: Procedura rapida per aggiornare periodicamente la calibrazione dello scanner o da eseguirsi in seguito allo spostamento dell...")
(Created page with "Questo strumento si avvale del Kit di Calibrazione per effettuare una ricalibrazione della Testa Ottica dello scanner. La procedura si sviluppa come segue:")
Line 19: Line 19:
 
; Calibrazione Completa: Procedura più complessa da eseguirsi dopo una riparazione di tipo meccanico all'hardware
 
; Calibrazione Completa: Procedura più complessa da eseguirsi dopo una riparazione di tipo meccanico all'hardware
  
This tool uses the [[Accessories|Calibration Kit]] to carry out a new calibration of the Optical Head of the scanner. The procedure is the following:
+
Questo strumento si avvale del [[Accessories|Kit di Calibrazione]] per effettuare una ricalibrazione della Testa Ottica dello scanner. La procedura si sviluppa come segue:
  
 
#Put the calibration kit inside the scanner in the correct position
 
#Put the calibration kit inside the scanner in the correct position

Revision as of 13:16, 12 May 2017


Per calibrare, accedere all'area modalità Service dalla pagina di benvenuto cliccando su Service.

Welcome.png

La pagina Service permette all'utente di controllare la connessione dello scanner e di eseguire tutte le calibrazioni di cui lo scanner necessita per funzionare correttamente. Per saperne di più, vedi la pagina Service.

In questa pagina si chiarirà come calibrare lo scanner.

Ricalibrare la Testa

Per avviare questo strumento, cliccare sul bottone Calibrazione Testa HeadCalibAction.png;

Calib-panel.png

Esistono 2 tipi di calibrazione:

Ricalibrazione
Procedura rapida per aggiornare periodicamente la calibrazione dello scanner o da eseguirsi in seguito allo spostamento dello scanner in un'altra posizione
Calibrazione Completa
Procedura più complessa da eseguirsi dopo una riparazione di tipo meccanico all'hardware

Questo strumento si avvale del Kit di Calibrazione per effettuare una ricalibrazione della Testa Ottica dello scanner. La procedura si sviluppa come segue:

  1. Put the calibration kit inside the scanner in the correct position
  2. Select the calibration type from the drop-down menu
  3. In the calibration dialog, select from the drop down menu the exact calibration kit name
  4. Click Start

If the calibration kit name is not available in the drop down menu, the Load New Master Xml button can be used to add a new calibration kit from the appropriate Xml description file.

Service-master.png

The calibration procedure is automatic. Once finished, the software will show one of the following messages:

  • 'Scanner Already Calibrated' : the calibration is not necessary
  • 'Scanner Recalibrated Successfully' : the calibration has been completed
  • 'Scanner Recalibration Failed' : calibration has to be repeated

If the calibration was successful, the Axes Calibration starts automatically.

Recalibrate Axes

This tool is used to check the movement system of the scanner. The scanner will scan an object, analyze it, and use this data to calibrate the movement system.

This tool will start automatically after a Head Recalibration or can be started manually with the AxisCalibAction.png button.


When the Dynamic Articulation Module is enabled, calibrate the axis with the specific Axis Calibration Object. From that moment on, any recalibration needs to be performed with the same object. Otherwise, axis recalibration will fail.

The software will show an image of the object needed to calibrate the scanner: either the calibration object (if the Dynamic articulation module is active on the license) or a stone model.

Axes cal.png

  1. Put the calibration object inside the scanner
  2. Click Recalibrate Axis
  3. Click Ok when prompted

The calibration procedure is automatic. Once it is finished, the software will show one of the following messages:

  • 'Axes Recalibration Successfull' : the calibration has been completed,
  • 'Axes Recalibration Successfull, Dynamic Articulation Calibration Failed' : the calibration has been completed, however the dynamic articulation positioning will not work. This message shows when the dynamic articulation module is active on the license, but the scanner has been calibrated with a normal stone model.
  • 'Axes Recalibration Failed' : calibration has to be repeated

Color Calibration

This last calibration, that can be opened by clicking on the icon ColorCalibAction.png, allows to calibrate the acquired colors of the scanner to have realistic color results.

To calibrate the colors, hold a piece of paper in front of the cameras, as prompted by the message, and click OK.

Service-colors-message.png

It is important that the whole field is covered by the white paper. Take a look at the following pictures to replicate a correct positioning of the white sheet.

Paper-position.png