Open main menu

Changes

Scan

No change in size, 6 years ago
no edit summary
;{{List button|importAction.png}} Import: Allows to import a file for the required image instead of scanning. This icon is always available.
;{{List button|advAction.png}} Advanced parameters: Allows to set a different scanning procedure for the ongoing step. This action will be better explained later in this page.
;{{List button|copyRefAction.png}} Copy from Reference: Allows to copy an image previously acquired for the ongoing step. This action is available in the Helthy healthy and pontics, and in the Waxup scanning steps. This action is fully automatic, which means the copied image is already shown in the step without having to click on the relevant icon. The user can still decide to scan the object again and then to copy the frist first reference if the last scan is not satisfactory.;{{List button|nextAction.png}} Next: Goes forward one step forward in the project. This icon is available when the ongoing step is complete or in steps that can be skipped.
<!--T:7-->
<!--T:12-->
; Follow View: Click on '''Follow View'''. Move the 3d 3D object in the space and center the view on the missing information. Check that the point that you need to scan again is visible in the live view of the cameras and click on '''Integrate'''.
<!--T:13-->
<!--T:19-->
Every object is scanned with a different procedure, to get all the details of the different shapes that can be scanned and avoid to use an unnecessarirly unnecessarily elevated number of images for a reference object. For instance, the articulation scan will be performed with only four images on an horizontal plane plan and reduced speed to avoid loosing the balance of the occlusion; on the other hand, the models will be scanned with 6 images on a low tilt, the dies with 12 images on a higher tilt and so on.
<!--T:20-->
These '''profiles''' are Open Technologies' suggestion on how to scan a determined object, but it is not said that they should be always the best procedures, seen that dental objects are seldom similar. Starting from this assumption, the user is always free to decide whether to change the scan profile or not by selecting any other voice in the profile list to increase or reduce the number of images and detail. Of course, the higher the level of detail, the hhigher higher the number of images, the heavier the resulting file.
<!--T:21-->
<!--T:23-->
There are two parameters atht that can be modified:
<!--T:24-->
;Object Color: The shade of the specific kind of object. Like in the live view of the camarascameras, this parameters parameter controls the amount of light that will hit the object; if the object is very dark it will need to be scanned with a brighter beam and vice versa.;Scan StrenghtStrength: This parameter allows to higher the contrast of the scanning pattern to better scan difficult surfaces (translucid, metallic etc). The more the selected strenghtstrength, the more time the scan will take.
===Die Scan Definition=== <!--T:25-->
<!--T:28-->
The multi die definiton {{Inline button|mdSetupAction.png}} appear appears automatically at the beginning of the dies scanning step. The 9 positions of the multi die will be filled starting from the elements of the first quadrant, if there are any, and follows the standard numbering order. The wizard will show in which position to insert each die. If the dies exceed the number of positions, a further step will be added to the wizard to scan all the elements defined in the project. <br />
If the multi die plate is used, the software will already know which die is in which position, and there will be no need to further identify the items that will be automatically aligned to their reference.
<!--T:31-->
The software will mark all the items to be scanned in the same color which means that, by default, they would need to be scanned together. By clicking on one of the items to scan, the tooth will change color and will create a second scan group. Click then on all the items to be scanned in that second scan group. By clicking a second time on one of the already selected items, a further scan group will be created and marked in a third color. This operation can be repeated as many times as one wishes, remeber remember that '''all the items marked in the same color will be scanned together'''. <br />
In this mode, the software cannot know which item is scanned in which position, therefore it will require the user to identify each stump. Identification procedure will be explained in the [[Edit|Edit Tools]] page.
<!--T:35-->
The software will mark all the items to be scanned in the same color which means that, by default, they would need to be scanned together. By clicking on one of the items to scan, the tooth will change color and will create a second scan group. Click then on all the items to be scanned in that second scan group. By clicking a second time on one of the already selected items, a further scan group will be created and marked in a third color. This operation can be repeated as many times as one wishes, remeber remember that '''all the items marked in the same color will be scanned together'''. <br />
The software cannot know which marker is scanned in which position, therefore it will require the user to identify each scanbody. Identification procedure will be explained in the [[Edit|Edit Tools]] page.
4,327

edits