Difference between revisions of "Scan/ja"

From Dental Wiki
Jump to navigation Jump to search
(Created page with "'''アドバンス設定'''ボタン {{Inline button|advAction.png}} をクリックすると、プロファイルおよびパラメーターの選択ダイアログが開き...")
(Created page with "すべてのオブジェクトは異なる手順でスキャンされます。これはスキャン可能なさまざまな形状ですべての詳細情報を取得すると...")
Line 43: Line 43:
 
[[File:free-profiles-scan.png]]
 
[[File:free-profiles-scan.png]]
  
Every object is scanned with a different procedure, to get all the details of the different shapes that can be scanned and avoid to use an unnecessarily elevated number of images for a reference object. For instance, the articulation scan will be performed with only four images on an horizontal plan and reduced speed to avoid loosing the balance of the occlusion; on the other hand, the models will be scanned with 6 images on a low tilt, the dies with 12 images on a higher tilt and so on.
+
すべてのオブジェクトは異なる手順でスキャンされます。これはスキャン可能なさまざまな形状ですべての詳細情報を取得すると同時に、レファレンスオブジェクト用の画像を取得する際に不要な数を取得しないようにするためです。例えば、咬合器スキャンでは、水平面での画像を4枚だけ取得して、咬合のバランスを失わないようにスピードを落としますが、模型では低いチルトで6枚の画像を、ダイでは高いチルトで12枚の画像をスキャンします。
  
 
These '''profiles''' are Open Technologies' suggestion on how to scan a determined object, but it is not said that they should be always the best procedures, seen that dental objects are seldom similar. Starting from this assumption, the user is always free to decide whether to change the scan profile or not by selecting any other voice in  the profile list to increase or reduce the number of images and detail. Of course, the higher the level of detail, the higher the number of images, the heavier the resulting file.
 
These '''profiles''' are Open Technologies' suggestion on how to scan a determined object, but it is not said that they should be always the best procedures, seen that dental objects are seldom similar. Starting from this assumption, the user is always free to decide whether to change the scan profile or not by selecting any other voice in  the profile list to increase or reduce the number of images and detail. Of course, the higher the level of detail, the higher the number of images, the heavier the resulting file.

Revision as of 01:46, 22 September 2017


構造

スキャンインターフェースは、ウィザードで3D画像の取得を制御する部分です。メインのツールバーにはスキャン用のツールがあり、右上にあるカメラのライブビューではスキャンチャンバー内のオブジェクトの位置やあてられている光量を確認できます。

Wizard-interface-scan.png

スキャンツールバー

スキャンツールバーでの操作は実行中の手順によって異なることがあります。表示されるすべてのアイコンのリスト、用途、および表示されるステップを以下に示します。

PrevAction.png 戻る
前のステップに戻ります。最初のスキャンステップでは、アイコンが無効になっています。
ScanAction.png スキャン
実行中のステップ固有の取得手順を開始します。このアイコンは常に利用可能です。
IntegrateAction.png 統合
実行中のステップで取得済みのものに画像を追加できます。咬合器スキャンステップ中、またはスキャンを実際に実行する前は、このアイコンは利用できません。この操作については、このページの下部で詳しく説明します。
ImportAction.png インポート
スキャンする代わりに、必要な画像のファイルをインポートできます。このアイコンは常に利用可能です。
AdvAction.png 詳細パラメーター
実行中のステップで異なるスキャン手順を設定できます。この操作については、このページの下部で詳しく説明します。
CopyRefAction.png レファレンスからコピー
実行中のステップで以前取得した画像をコピーできます。この操作は、健全歯およびポンティックで利用可能で、ワックスアップのスキャンステップでも利用できます。この操作は完全に自動化されているので、該当するアイコンをクリックしなくてもコピーされた画像はすでに表示されています。前回のスキャンの結果が思わしくない場合、ユーザーはオブジェクトを再スキャンしてから最初のレファレンスをコピーできます。
NextAction.png 次へ
プロジェクトの次のステップに進みます。実行中のステップが完了している、またはスキップできる場合、このアイコンは利用可能です。

スキャンを起動すると、進行状況を示すホイールが表示されます。スキャンを中止する場合は、StopAction.png ボタンをクリックします。

統合

統合アクションでは、オブジェクトを再スキャンせずに、スキャンに情報を追加できます。IntegrateAction.png ボタンをクリックすると、統合パネルが開きます。

Integrate-actions.png

統合を実行するには2つの方法があります。該当するボタンをクリックして統合する方法を選択してから、統合ボタンをクリックして統合を開始します。

フォロービュー
Follow View(フォロービュー)をクリックし、3Dオブジェクトを動かして情報が不足している部分を中心に表示させます。再スキャンする必要のある部分がカメラのライブビューに表示されていることを確認し、Integrate(統合)をクリックします。

Follow.gif

スマート
Smart(スマート)をクリックすると、小さい進行状況バーが表示され、100%になると不足している情報や穴になっている部分が、実際の画像上ですべて黄色でマークされます。再スキャンが必要な部分を選択するには、その黄色の線の近くで左クリックします。選択された領域は赤色でマークされます。integrate(統合)をクリックすると、スキャン処理が起動し、不足している情報の部分が補われます。

Smart.gif

アドバンス設定

アドバンス設定ボタン AdvAction.png をクリックすると、プロファイルおよびパラメーターの選択ダイアログが開きます。

Free-profiles-scan.png

すべてのオブジェクトは異なる手順でスキャンされます。これはスキャン可能なさまざまな形状ですべての詳細情報を取得すると同時に、レファレンスオブジェクト用の画像を取得する際に不要な数を取得しないようにするためです。例えば、咬合器スキャンでは、水平面での画像を4枚だけ取得して、咬合のバランスを失わないようにスピードを落としますが、模型では低いチルトで6枚の画像を、ダイでは高いチルトで12枚の画像をスキャンします。

These profiles are Open Technologies' suggestion on how to scan a determined object, but it is not said that they should be always the best procedures, seen that dental objects are seldom similar. Starting from this assumption, the user is always free to decide whether to change the scan profile or not by selecting any other voice in the profile list to increase or reduce the number of images and detail. Of course, the higher the level of detail, the higher the number of images, the heavier the resulting file.

Moreover, by clicking Advanced on the bottom of the dialog, the user will be able to change some advanced parameters of the selected scanning profile.

Free-advancedpar-scan.png

There are two parameters that can be modified:

Object Color
The shade of the specific kind of object. Like in the live view of the cameras, this parameter controls the amount of light that will hit the object; if the object is very dark it will need to be scanned with a brighter beam and vice versa.
Scan Strength
This parameter allows to higher the contrast of the scanning pattern to better scan difficult surfaces (translucid, metallic etc). The more the selected strength, the more time the scan will take.

Die Scan Definition

Die scanning works the same as all the other scanning steps, but it has an intermediate definition step with which the user can decide to either use the Multi die plate (default choice) or to mark a custom die scan setup.

Wizard-multidie-def.png

The multi die definiton MdSetupAction.png appears automatically at the beginning of the dies scanning step. The 9 positions of the multi die will be filled starting from the elements of the first quadrant, if there are any, and follows the standard numbering order. The wizard will show in which position to insert each die. If the dies exceed the number of positions, a further step will be added to the wizard to scan all the elements defined in the project.
If the multi die plate is used, the software will already know which die is in which position, and there will be no need to further identify the items that will be automatically aligned to their reference.

As an alternative to the use of the multi die plate, the user can set a custom die scan order by clicking on the custom setup CustomSetupAction.png button.

Wizard-diescan.png

The software will mark all the items to be scanned in the same color which means that, by default, they would need to be scanned together. By clicking on one of the items to scan, the tooth will change color and will create a second scan group. Click then on all the items to be scanned in that second scan group. By clicking a second time on one of the already selected items, a further scan group will be created and marked in a third color. This operation can be repeated as many times as one wishes, remember that all the items marked in the same color will be scanned together.
In this mode, the software cannot know which item is scanned in which position, therefore it will require the user to identify each stump. Identification procedure will be explained in the Edit Tools page.


Marker Scan Definition

The marker (or scanbodies) scan is similar to the custom setup of the dies scan.

Wizard-markerscan.png

The software will mark all the items to be scanned in the same color which means that, by default, they would need to be scanned together. By clicking on one of the items to scan, the tooth will change color and will create a second scan group. Click then on all the items to be scanned in that second scan group. By clicking a second time on one of the already selected items, a further scan group will be created and marked in a third color. This operation can be repeated as many times as one wishes, remember that all the items marked in the same color will be scanned together.
The software cannot know which marker is scanned in which position, therefore it will require the user to identify each scanbody. Identification procedure will be explained in the Edit Tools page.

Live view

The live view of the software, on the upper right corner, allows to check the position of the object and the amount of light with which it will be scanned.
For different objects in the same project the light might need to be changed to avoid reflections and improve the scan quality.

The light intensity can be regulated using the bar on the left side of the window.

Light.gif

The red markings show the areas of the objects that are over-exposed and will be more problematic to acquire. Be careful not to lower too much the light intensity, as to do so, the scan quality will be worsened.

Navigation Back.png Homebutton.png Navigation Next.png